Instructions:
www.garyklinka.com
- Print
these pages.
- Circle
the correct answers.
- Page down
to the last page for the verification forms and mailing instructions.
- Click
and print….. Comm 81,
Comm 82,
and Comm
84 if needed to answer the questions below.
6 hours of credit
- A person may obtain a
license as a licensed master plumber by either:
a)
Taking and passing the master plumber license
examination;
b)
Possessing a master plumber license–retiree.
c)
neither a or b
d)
both a or b
- A person applying for a
master plumber license examination shall have one of the following
qualifications:
a)
At least 1,000 hours of experience per year for at
least 3 consecutive years as a licensed journeyman plumber.
b)
Graduated from an accredited engineering university or
college with a degree in civil engineering, mechanical engineering or other
approved engineering curriculum related to plumbing.
c)
A licensed master plumber from another state recognized
by the State of Wisconsin.
d)
only a or b
- A person who has exchanged
his or her master plumber license for a journeyman plumber license may,
upon application to the department, exchange his or her journeyman plumber
license for a master plumber license provided:
1. The person holds a valid journeyman plumber license.
2. The person submits with the application a copy of his
or her
former master plumber license.
3. The license fee for a master plumber specified in s.
Comm 5.02, Table 5.02 is submitted.
a)
true
b)
false
- The provisions of chapter ________
apply uniformly to the design, construction, installation, supervision,
maintenance and inspection of plumbing, including but not limited to sanitary
and storm drainage, water supplies, wastewater treatment, and dispersal or
discharge for buildings.
a)
81
b)
82
c)
83
d)
84
- The provisions of chapter
82 are retroactive, unless specifically stated otherwise in the rule.
a)
true
b)
false
- Proper protection shall be
provided to prevent contamination of food, water, sterile goods and
similar materials by backflow of wastewater.
a)
true
b)
false
- To fulfill the basic needs
of sanitation and personal hygiene, each dwelling shall be connected to a
POWTS or public sewer and be provided with at least the following plumbing
fixtures: one water closet, one wash basin, one kitchen sink and one
bathtub or shower, except a system or device recognized under ch. Comm 91
may be substituted for the water closet. All other structures for human
occupancy shall be equipped with sanitary facilities in sufficient numbers
as specified in chs. Comm 61 to 65.
a)
true
b)
false
- SUBMITTALS TO DEPARTMENT: Except
for direct replacement, new installations, additions and alterations to
drain systems, vent systems, water service systems, and water distribution
systems involving more than 16 plumbing fixtures to be installed in
connection with public buildings.
a)
true
b)
false
- An agent municipality
shall employ 1 full time plumbing inspector who has been qualified by the
department.
a)
true
b)
false
- Plans and specifications
for pubic buildings. (a) At least 3 sets of plans and one copy of
specifications which are clear, legible and permanent copies shall be
submitted for examination and approval.
a)
true
b)
false
- The air test for a drain
and vent system shall be made by attaching an air compressor testing
apparatus to any suitable opening, and, after closing all other inlets and
outlets to the system, forcing air into the system until there is a uniform
gauge pressure of 3 pounds per square inch. This pressure shall be held
without introduction of additional air for a period of at least 5 minutes.
a)
true
b)
false
- The smoke test shall be
made by introducing a pungent, thick smoke, produced by one or more smoke
machines, into the completed system. When the smoke appears at stack
openings on the roof, the openings shall be closed and a pressure
equivalent to_______________shall be built and maintained for the period
of the inspection.
a)
3 pounds per square inch
b)
a one inch water column
c)
a 10 foot head of water
d)
a, b, and c
- Water supply piping
materials may only be reused when intended for uses having an equal or
higher degree of hazard than the previous use.
a)
true
b)
false
- When old or defective plumbing is to
be remodeled, additional fixtures installed, or the whole plumbing system
moved to another part of the building, the remodeled system shall be made
to conform to this chapter.
a)
true
b)
false
- Double check backflow
prevention assembly, ASSE 1015, the test results must be submitted to the
Department and the Purveyor.
a)
true
b)
false
- Pressure vacuum breaker
assembly, ASSE 1020, ASSE 1015, the test results must be submitted to the
Department and the Purveyor.
a)
true
b)
false
- The indirect or local waste
piping serving a water heater temperature and pressure relief valve, water
treatment device, cross connection control device or assembly, or a
furnace or air conditioner shall discharge to a floor served by a floor
drain so as not to create a health or safety hazard.
a)
true
b)
false
- Single family dwelling-A
control valve shall be installed in the supply piping to each water heater
and water treatment device and in the fixture supply to each water closet,
exterior hose bibb, kitchen sink, plumbing appliance and piece of
equipment.
a)
true
b)
false
- The temperature and
pressure relief valve discharge pipe of a water heater shall be installed
to drain by gravity flow to a floor served by a floor drain or to
standpipe in accordance with s. Comm 82.33 (8).
a)
true
b)
false
- The outlet of the
temperature and pressure relief valve discharge pipe of a water heater
shall terminate within 6” over the floor or receptor, but not less than a
distance equal to twice the diameter of the inlet pipe.
a)
true
b)
false
- Inspection of one-and
2-family dwellings. The inspection of plumbing installations for
one- and 2-family dwellings shall be in accordance with ss. Comm _____________.
a)
20
b)
21
c)
22
d)
23
- Equipment, materials and labor
for tests. All equipment, materials and labor required for testing a
plumbing system or part thereof shall be furnished by the _______________.
a)
contractor
b)
inspector
c)
plumber
d)
either a, b, or c
- The building sewer or
private interceptor main sewer shall be tested by insertion of a test plug
at the point of connection with the public sewer. The sewer shall then be
filled with water under a head of not less than 10 feet. The water level
at the top of the test head of water shall not drop for at least 5
minutes.
a)
true
b)
false
- The drainage fixture unit
values assigned to a receptor which is to receive only the indirect waste
discharge from a relief valve on a domestic water heater may be
disregarded when determining the minimum size of the building drain and
building sewer.
a)
true
b)
false
- Drainage fixture unit
values for intermittent flow fixtures not listed in Table 82.30-1 shall be
computed on the basis of one fixture unit equaling _____ gallons per
minute of flow.
a)
6.5
b)
7
c)
7.5
d)
8
- Drainage fixture unit
values for a breakroom single compartment sink would be?
a)
½
b)
1
c)
1 ½
d)
1 ¼
- Drainage fixture unit
values for a residential automatic clothes washer would be?
a)
2
b)
2 ½
c)
3
d)
3 ½
- Minimum trap size for a
residential automatic clothes washer would be?
a)
1 ¼”
b)
1 ½”
c)
2”
d)
Trap size corresponds to the size of the drain outlet
- Bathroom Group includes:
water closet, lavatory, bathtub and shower.
a)
true
b)
false
- Trap size for a water
closet, non public would be?
a)
3”
b)
4”
c)
both a & b
d)
Trap size specified in referenced standards of s. Comm
84.20.
- Pressurized building
sewers shall be sized not less than ___ in diameter for sewage ejectors
and sewage pumps, and ___ in diameter for all sewage grinder pumps.
a)
3”, 2”
b)
2”, 1 ¼”
c)
2”, 1 ½”
d)
3”, 1 ½”
- The minimum size of a
gravity flow sanitary building sewer shall be ___